Shopping Cart | Wish List | Gift Registry | Customer Service  
 
Search:  
   
  Login
 
Credit Card Safe
 
Skip Navigation Links.
 

 
 
 

Help & Info
 

To find answers to most common questions visit our FAQ page

If your question remains unanswered contact us


 

Poll
 
(!POLL!)
View Poll Results
 
 
 



Welcome to Golem Gear 



 Golem Gear

Trogloxenes Tek Divers Rock Tek divers rock CCR Beyond Extreme On the loop CCR Cave diver Just killing Time Tight Squeeze Golem gear
Checkout our hottest specials!
Golem CCR Ring wing

Technical wing specifically designed for rebreathers. The circular design distribubutes the gas evenly in any position. The wing is narrow at the top to limit interference with rebreather hoses. It is wider to ensure full inflation away from the stack and backplate, while tapered at the bottom to allow easy access to tank valves..

The wing has been redesigned with slots to streamline hose and cable routing.

This wing is ideal for use with rebreathers. Its simple, streamlined design paired with low profile Golem Stream backplate creates unbeatable CCR kit.

Rock solid construction. Streamlined for effortless swimming, low drag for scootering. Circular, doughnut, ring shape.

20kg/45 lbs lift

height 24"
width 24"
lowest grommet hole to bottom of hose cutouts 2"

Wing Cover:
Outer abrasion resistant shell made from Cordura 2000

Wing bladder: inner bladder made from RF welded CORDURA 560 with PU coating. It resists hydrolysis, low temperatures, and hydrocarbons.

Virtually indestructible.
High quality Swiss RiRi zipper. Available in Black.

ccr high quality inflator and provtected elbow
GolemCCR wing fitted to HH CCR Inflator hose with protection sleeve at the elbow Hi quality SS inflator with SS insert

 

 

Regular Price: $380.00
On Sale For: $290.00 

No helium sensor to replace - ever!

Hi-tech analyzer for measuring  nitrox and trimix gases.  After inserting the analyzer adapter (included) to a bottle valve with a breathing mixture, the content of both oxygen and helium is shown as percentages directly on the display at the same time.

SET INCLUDES
- Standard flow limiter for all valves.
- Worldwide Power Supply (also works with 9V battery - included)
- Hard and watertight Case
- Connection hose
- Ohmmeter plug-in
- Voltmeter plug-in
- Measuring cables

This trimx analyser reports "FOUL AIR" if the oxygen, nitrogen and helium can not be calculated due to contamination which is a major safety advantage over any other analyser.

 
Features 
  • OLED Display
  • Analyzer has built in Gas Mixing Calculator
  • Continous flow mixture measurement with Hi/Lo alarms for He and O2
  • new electronics with lower energy usage
  • Gas purity option serves for gas purity measuring.
    It is primary suited for argon, but after readjustment of the values it is possible to use for several different gases.
    It is also possible to detect ratio of two gases with different speed of sound. For example: helium/nitrogen, helium/argon, hydrogen/nitrogen, hydrogen/argon and many more.

  Video  Video
 


Operation Principle

A standard electrochemical sensor (R-17D) normally used in analyzers for diving is used to determine the oxygen content. The helium content is determined on the basis of measuring the speed of sound in the analyzed mixture.

The speed of sound depends on the content of helium and oxygen, and on the temperature of the mixture. The dependence of the speed of sound on pressure is marginal and can be ignored under normal atmospheric pressure. At 0°C the speed of sound is approximately 970 m/s in pure helium, 330 m/s in air, and 315 m/s in pure oxygen. Raising the temperature by one degree raises the speed of sound by approximately 0.175%. The speed of sound in the mixture is described as a non-linear equation of temperature, oxygen content and helium content.

The speed of sound is measured directly as the time it takes for an acoustic impulse to travel between two microphones. This measurement is taken alternately in both directions to eliminate the influence of the gas flow-rate.

Calibration
 
Every analyzer produced is tesed in the complete range of acceptable oxygen and helium values. It is tested in air, pure oxygen and pure helium as well as in 12 different calibration mixtures.
 
Includes
- Simple flow limiter for all valves.
- Worldwide Power Supply (also works with 9V battery - included)
- Hard and watertight Case.
-  professional flow limiter
-  connection hose
- spare set of O-rings
 
OPTIONAL
Pressure sensor - the analyzer can measure pressure in the tank and gas mixture at the same time
Ohm-meter plugin - to check bulbs and cables 
Voltmeter plug-in - to check batteries (lights, scooters...)
Flow Limiter for Inflator
 

Firmware upgrades

The firmware in the He/O2 analyzer is continuously updated. The updates are user installable and can be downloaded here:
Price: $1,090.00 

Combo comes with 35 lbs. wing, tank bands, SS backplate with harness and FREE harness knife.

Golem Gear Knife

Golem 35 wing:

Technical wing for single tank configuration. Rock solid construction. Streamlined for effortless swimming, low drag for scootering.

These wings are designed specifically for use with single cylinders. They provide  35 pounds/18l of lift. They are designed for use with Aluminium and Steel single tanks.  A 24-inch/60cm low-pressure inflator hose is included. Available in Black.

This wing is ideal for use with rebreathers. Its simple, streamlined design paired with low profile Golem Stream backplate creates unbeatable CCR kit.

Wing Cover:  Outer abrasion resistant shell made from Cordura 2000

Wing bladder: inner bladder made from RF welded CORDURA 560 with PU coating. It resists hydrolysis, low temperatures, and hydrocarbons. 

 Virtually indestructible. High quality Swiss RiRi zipper. Two cam bands with stainless steel buckles and LP hose included. Two backplate attachment SS bolts and nuts are also included.

high quality inflator and provtected elbow
Inflator hose with protection sleeve at the elbow Hi quality SS inflator with SS insert

Regular Price: $530.00
On Sale For: $380.00 

No helium sensor to replace - ever!

Hi-tech analyzer for measuring  nitrox and trimix gases.  After inserting the analyzer adapter (included) to a bottle valve with a breathing mixture, the content of both oxygen and helium is shown as percentages directly on the display at the same time.

SET INCLUDES
- Professional flow limiter for all valves.
- Worldwide Power Supply (also works with 9V battery - included)
- Hard and watertight Case
- Connection hose
- Ohmmeter plug-in
- Voltmeter plug-in
- Measuring cables

This trimx analyser reports "FOUL AIR" if the oxygen, nitrogen and helium can not be calculated due to contamination which is a major safety advantage over any other analyser.

 
Features 
  • OLED Display
  • Analyzer has built in Gas Mixing Calculator
  • Continous flow mixture measurement with Hi/Lo alarms for He and O2
  • new electronics with lower energy usage
  • Gas purity option serves for gas purity measuring.
    It is primary suited for argon, but after readjustment of the values it is possible to use for several different gases.
    It is also possible to detect ratio of two gases with different speed of sound. For example: helium/nitrogen, helium/argon, hydrogen/nitrogen, hydrogen/argon and many more.

  Video  Video
 


Operation Principle

A standard electrochemical sensor (R-17D) normally used in analyzers for diving is used to determine the oxygen content. The helium content is determined on the basis of measuring the speed of sound in the analyzed mixture.

The speed of sound depends on the content of helium and oxygen, and on the temperature of the mixture. The dependence of the speed of sound on pressure is marginal and can be ignored under normal atmospheric pressure. At 0°C the speed of sound is approximately 970 m/s in pure helium, 330 m/s in air, and 315 m/s in pure oxygen. Raising the temperature by one degree raises the speed of sound by approximately 0.175%. The speed of sound in the mixture is described as a non-linear equation of temperature, oxygen content and helium content.

The speed of sound is measured directly as the time it takes for an acoustic impulse to travel between two microphones. This measurement is taken alternately in both directions to eliminate the influence of the gas flow-rate.

Calibration
 
Every analyzer produced is tesed in the complete range of acceptable oxygen and helium values. It is tested in air, pure oxygen and pure helium as well as in 12 different calibration mixtures.
 
Includes
- Simple flow limiter for all valves.
- Worldwide Power Supply (also works with 9V battery - included)
- Hard and watertight Case.
-  professional flow limiter
-  connection hose
- spare set of O-rings
 
OPTIONAL
Pressure sensor - the analyzer can measure pressure in the tank and gas mixture at the same time
Ohm-meter plugin - to check bulbs and cables 
Voltmeter plug-in - to check batteries (lights, scooters...)
Flow Limiter for Inflator
 

Firmware upgrades

The firmware in the He/O2 analyzer is continuously updated. The updates are user installable and can be downloaded here:
Price: $1,150.00 

The Best of Golem Gear Harness/BP/Wing combo
We have combined our best wings with our Stream low profile SS backplate and revolutionary new G2 adjustable harness into unbeatable combo package suitable for any type of diving.


Golem Stream Backplate

Inspired by expedition divers' minimalist needs and designed by traveling rebreather divers.

This stainless steel backplate weighs only 2 lbs. and due to it's unique reversed design it will accommodate rebreather scrubber canisters as well as single tanks without the need for cumbersome and redundant adapters (STAs).

Can be quickly mounted with a pair of cam bands and will accommodate the Golem Gear Armadillo CCR and/or any brand of buoyancy wings.
 
The BP is 15 inches long by 11 inches wide.

The G2 adjustable diving harness is a streamlined webbing harness with all the standard D-rings. We added heavy duty SS adjustable buckles to shoulder straps. The straps can be loosened to don the rig and cinch the straps down. When removing, loosen the shoulder straps, open the buckle and walk out of the harness.
The buckles are heavy duty stainless steel used on Search and Rescue (SAR) harnesses world wide - if they can lift two people into helicopter they will hold the kit on your back. G2 HarnessOptionally, heavy duty SAR plastic buckles are available for light-weight travel setup.


Fits on any standard backplate or rebreather.

 
Download configuration manual.






Crotch strap not included. Order separately.




Fits on any standard backplate or rebreather.



Select either
  • Combo Single -  35lbs Ring (doughnut) single tank wing with the BP and harness
  • Combo Double -  50bs Ring (doughnut) double tanks wing with the BP and harness
  • Combo CCR -  35lbs CRR wing specially designed for rebreathers  with the BP and harness

No matter which one you choose you cannot go wrong with comfort, reliability and ruggedness of Golem Gear.

Regular Price: $520.00
On Sale For: $440.00 

more...